Papers publicated on Journals
1. T. FUKUDA, S. GUO, J. WANG, K. KOSUGE and F. ARAI, "Artificial Muscular
Type of Actuators - Structure and Characteristics of Serial-Parallel Type
of Pneumatic Actuator - ", IFToMM-jc International Symposium on Theory
of Machines and Mechanisms, pp. 862-867, Nagoya, JAPAN, Sep. 24-26, 1992.
2. S. GUO, T. FUKUDA, K. KOSUGE, F. ARAI, "Active Catheter System with
Multi Degrees of Freedom -Mechanism and Experimental Results of Active Catheter
with Multi Units and Multi D. O. F.", Fourth International Symposium
on Micro Machine and Human Science, pp.155-162, NAGOYA, JAPAN, Oct.13-15,
1993.
3. T. FUKUDA, S. GUO, K. KOSUGE, F. ARAI, M. NEGORO, K. NAKABAYASHI, "Micro
Active Catheter System with Multi Degrees of Freedom", Proceedings
IEEE International Conference on Robotic and Automation , pp. 2290-2295,
San Diego, USA, May.8-13, 1994.
4. S. GUO, T. FUKUDA, K. KOSUGE, F. ARAI, K. OGURO, M. NEGORO, "Micro
Catheter System with Active Guide Wire -Structure, Experimental Results
and Characteristic Evaluation of Active Guide Wire Catheter Using ICPF Actuator-",
Fifth International Symposium on Micro Machine and Human Science (MHS'94
), pp.191-197, Nagoya, JAPAN, Oct.2-4, 1994.
5. S. GUO, T. FUKUDA, K. KOSUGE, F. ARAI, K. OGURO, M. NEGORO, "Micro
Catheter System with Active Guide Wire",1995 IEEE Int. Conf. on Robotics
and Automation(ICRA)'95-Nagoya, Vol.1, pp.79-84, 1995.
6. S. GUO, T. FUKUDA, K. KOSUGE, F. ARAI, K. OGURO, M. NEGORO, "Micro
Active Guide Wire Catheter Using ICPF Actuator", IEEE Int. Conf. on
Intelligent Robotics and Systems(IROS)'95,Vol.2, pp.172-177, Pittsburgh,
Pennsylvania, USA, 1995.
7. S. GUO, T. FUKUDA, F. ARAI, K. OGURO, M. NEGORO, T, NAKAMURA, "Micro
Active Guide Wire Catheter System(Characteristic Evaluation, Electrical
Model and Operability Evaluation of Micro Active Catheter)", 6th International
Symposium on Micro Machine and Human Science (MHS'95 ), pp.131-136, Nagoya,
JAPAN, 1995.
8. S. GUO and T. NAKAMURA, Micro Active Guide Wire Catheter, Proc. of 4th
International Workshop on Advanced Motion Control, pp.729-734, Mie, JAPAN,
1996.
9. S. GUO, T. FUKUDA and T. NAKAMURA, Micro Active Guide Wire Catheter System-Characteristic
Evaluation, Electrical Model and Operability Evaluation of Micro Active
Catheter, Proc. of 1996 IEEE International Conf. on Robotics and Automation,
pp.2226-2231, Minneapolis, Minnesota, USA, (1996)
10. S. GUO and T. NAKAMURA, Micro Active Catheter Using ICPF Actuator -Characteristic
Evaluation, Electrical Model and Operability Evaluation of Micro Active
Catheter -, Proc. of IEEE the 22nd Annual International Conf. on Industrial
Electronics, Control, and Instrumentation, pp.1312-1317, Taipei, TAIWAN,
(1996)
11. S. GUO, T. NAKAMURA and T. FUKUDA, Designe and Characteristic Evaluation
of Micropump Using ICPF Actuator, 7th International Symposium on Micro Machine
and Human Science (MHS'96 ), pp.235-240,Nagoya, 1996.
12. S. GUO, T. NAKAMURA and T. FUKUDA, Micro Active guide Wire Catheter
System, Proc. of IEEE International Conf. on Industrial Technology (ICIT'96),
Shanghai, China, pp.517-521, 2-6 December 1996.
13. S. GUO, T. FUKUDA, T. NAKAMURA and K. OGURO, Development of the Micro
Pump Using ICPF Actuator, Proc. of 1997 IEEE International Conf. on Robotics
and Automation, pp.266-271, Albuquerque, New Mexico, USA, (Aprile 1997)
14. S. GUO, T. FUKUDA, T. NAKAMURA and K. OGURO, A New Type of Micropump
Using ICPF Actuator, Proc. of IEEE/ASME International Conf. on Advanced
Intelligent Mechatronics, Waseda University, Tokyo, Japan, 1997.
15. S. GUO, K.Wakabayashi, N. Kato ,T. FUKUDA, T. Nakamura and K. OGURO,
An Artificial Fish Robot Using ICPF Actuator, 8th International Symposium
on Micro Machine and Human Science (MHS'97 ), pp.205-210, Nagoya, 1997.
16. M. Khamesee, T. Nakamura, N. Kato,S. Guo and K. Mizutani, A Remot Micro-Manipulator
for Teleoperation Using Magnetic Levitation, 8th International Symposium
on Micro Machine and Human Science (MHS'97 ), pp.169-176, Nagoya, 1997.
17. S. GUO , T. FUKUDA , N. KATO and K. OGURO, Development of Underwater
Microrobot Using ICPF Actuator, Proc. of 1998 IEEE International Conf. on
Robotics and Automation, pp.1829-1834, Leuven, Belgium , (May 1998)
18. S. GUO, T. FUKUDA, X.CHEN and K. OGURO, Biomimetic Underwater Microrobot
Using ICPF Actuator, Proc. of the 3rd International Conf. on Advanced Mecheatronics(ICAM'
98), pp.312-317, Okayama, Japan, 1998.
19. S. GUO, T. FUKUDA, X.CHEN and K. OGURO, A New Type of Micropump for
Medical Application, Proc. of the 3rd International Conf. on Advanced Mecheatronics(ICAM'
98), pp.318-323, Okayama, Japan, 1998.
20. X.CHEN, S. GUO, T. FUKUDA, A VSS Disturbance Observer and Its Application,
Proc. of 1998 IEEE International Conf. on Control Application(CCA'98), Trieste,
Italy, 1998.
21. S. GUO, T. FUKUDA, Norihiko KATO and K. OGURO, A Fish-microrobot Using
ICPF Actuator, Proc. of 5th International Workshop on Advanced Motion Control(AMC'98),
pp.592-597, Portugal, 1998.
22.S. GUO, A New Type of Underwater Microrobot Using ICPF Actuator, Proc. of
the 7th International Youth Conf. on Robotics(7th IYCR), Vol.20, pp.563-569, Dalian, China (Accepted), 1998.
23.S. GUO, A New Type of Microump Using ICPF Actuator for Medical Application,
Proc. of the 3rd CAST(China Association for Science and Technology) Conf. of
Young Scientists, pp.367-370, Beijing, China, 1998.
24. S. GUO, S. HATA, K. SUGUMOTO, T. FUKUDA and X.Chen, Micro Active Catheter
System Using SMA Actuator, Proc. of IEEE International Workshop on Robot and
Human Communication, pp.666-671, Takamatsu, Japan, 1998.
25. X. Chen, M. Ishida, S. Guo and T. Fukuda, Control of the robot manipulator
by using sliding mode method, Proc. of IEEE International Workshop on Robot and Human
Communication, pp.682-687, Takamatsu, Japan, 1998.
26. N. KONDO, N. KATO, S. GUO and Y. NOMURA, Design of a Micro Autonomous Moving Robot,
Proc. of IEEE International Workshop on Robot and Human Communication, pp.227-232,
Takamatsu, Japan, 1998.
27. S. GUO, S. HATA, K. SUGUMOTO, T. FUKUDA and K. OGURO, A New Type of Capsule
Micropump Using ICPF Actuator, Proc.of 9th International Symposium on Micro Machine and
Human Science (MHS'98 ), pp.255-261, Nagoya (1998).
28. S. GUO, S. HATA, K. SUGIMOTO, T. FUKUDA and M. NEGORO, A New Type of Micro
Active Catheter System, Proc. of 1998 Symposium on ISSPR'98 on Image, Speech, Signal
Processing and Robotics, Vol.1, pp.335-340, Hong Kong, 1998.
29. S. GUO , S. HATA, K. SUGIMOTO, T. FUKUDA and K. OGURO, Development of A New Type
of Capsule Micropump, Proc. of 1999 IEEE International Conf. on Robotics and Automation,
pp.2171-2176, Detroit, USA (May, 1999).
30. S. GUO, N. KONDO and KATO, A Micro Intelligent Autonomous Moving Robot, Proc.of
1999 IEEE Hong Kong Symposium on Robotics and Control, Vol.1, pp.289-295, Hong Kong,
(July, 1999).
31. S. GUO, K. SUGIMOTO, T. FUKUDA and M. NEGORO, A New Type of Capsule Medical Micropump, Proc. of 1999 IEEE/ASME International Conf. on Advanced Intelligent Mechatronics, pp.55-60, Atlanta, GA, USA, (September,1999).
32. X. Chen, S. GUO, and T. FUKUDA, Vibration Suppression Control of Flexible Arms by Using Sliding Mode Method, Proc. of the 1999 IEEE International Conf. on Control Applications, pp.309-314, Hawai'i, USA, (August, 1999).
33. S. GUO, T. FUKUDA and K. OGURO, Development of an Artificial Fish Microrobot, Proc.of 10th International Symposium on Micro Machine and Human Science (MHS'99 ), pp.135-140, Nagoya (Vovember, 1999).
34. S. HATA, D.TORIGOE, A. ISHII, S.GUO, K.SUGIMOTO, Vision System for Micro-operation Assistance, Proc. of FCV'99, pp.133-137, (1999).
35. S. GUO, Micromechatronics for Medical Application (Development of Micro Active Catheter System and New Type of Micropumps), Proc.of China-Japan Workshop on Multidisciplinary Researches in Engineering, pp.30-34, Shanghai (Janu., 2000).
36. S. GUO, K.SUGIMOTO, S. HATA, K. OGURO, A Underwater Microrobot with Multi DOF, Proc. of International Symposium on Smart Structures and Microsystems (IS3M),pp.134-139,Hong Kong,(Oct., 2000).
37. S. GUO, K.Sugimoto, S. Hata, Development of a Macro/Micro Mechanism for Human Scale Teleoperating System, Proc.of 11th International Symposium on Micro Machine and Human Science (MHS'20 ),pp.163-168, Nagoya (Oct, 2000).
38. S. GUO, K.Sugimoto, S. Hata,J.Su, K.Oguro, A New Type of Underwater Fish-like Microrobot, IEEE Int. Conf. on Intelligent Robotics and Systems(IROS)'20, pp.867-862,Kagawa, Japan(Nov.,2000)
39. S. GUO, K.Oguro, Microsystems for Bio-medical Applications (Development of Micro Active Catheter System and New Type of Micropumps), Proc.of 2000 International Conf. On Information Society in the 21st Century, Emerging Technologies and new challenges (IS2000),pp.314-320, Aizu, Japan(Nov.,2000)
Presentations
1. T. FUKUDA, S. GUO, K. KOSUGE, F. ARAI, M. NEGORO, K. NAKABAYASHI, "Micro
Active Catheter System with Multi Degrees of Freedom", Proceedings
IEEE International Conference on Robotic and Automation , pp. 2290-2295,
San Diego, USA, May.8-13, 1994.
2. S. GUO, T. FUKUDA, K. KOSUGE, F. ARAI, K. OGURO, M. NEGORO, "Micro
Active Guide Wire Catheter Using ICPF Actuator", IEEE Int. Conf. on
Intelligent Robotics and Systems(IROS)'95,Vol.2, pp.172-177, Pittsburgh,
Pennsylvania, USA, 1995.
3. S. GUO, T. FUKUDA and T. NAKAMURA, Micro Active Guide Wire Catheter System-Characteristic
Evaluation, Electrical Model and Operability Evaluation of Micro Active
Catheter, Proc. of 1996 IEEE International Conf. on Robotics and Automation,
pp.2226-2231, Minneapolis, Minnesota, USA, (1996)
4. S. GUO and T. NAKAMURA, Micro Active Catheter Using ICPF Actuator -Characteristic
Evaluation, Electrical Model and Operability Evaluation of Micro Active
Catheter -, Proc. of IEEE the 22nd Annual International Conf. on Industrial
Electronics, Control, and Instrumentation, pp.1312-1317, Taipei, TAIWAN,
(1996)
5. S. GUO, T. NAKAMURA and T. FUKUDA, Micro Active guide Wire Catheter System,
Proc. of IEEE International Conf. on Industrial Technology (ICIT'96), Shanghai,
China, pp.517-521, 2-6 December 1996.
6. S. GUO, T. FUKUDA, T. NAKAMURA and K. OGURO, Development of the Micro
Pump Using ICPF Actuator, Proc. of 1997 IEEE International Conf. on Robotics
and Automation, pp.266-271, Albuquerque, New Mexico, USA, (Aprile 1997)
7. S. GUO , T. FUKUDA , N. KATO and K. OGURO, Development of Underwater
Microrobot Using ICPF Actuator, Proc. of 1998 IEEE International Conf. on
Robotics and Automation, pp.1829-1834, Leuven, Belgium , May 1998)
8.S. GUO, A New Type of Underwater Microrobot Using ICPF Actuator, Proc. of
the 7th International Youth Conf. on Robotics(7th IYCR), Vol.20, pp.563-569, Dalian, China, 1998.
9.S. GUO, A New Type of Microump Using ICPF Actuator for Medical Application,
Proc. of the 3rd CAST(China Association for Science and Technology) Conf. of
Young Scientists, pp. 367-370, Beijing, China, 1998.
10.S. GUO, S. HATA, K. SUGUMOTO, T. FUKUDA and X.CHEN, Micro Active Catheter System
Using SMA Actuator, Proc. of IEEE International Workshop on Robot and Human Communication,
Takamatsu, Kagawa, Japan(Accepted), 1998.
11.S. GUO, S. HATA, K. SUGUMOTO, T. FUKUDA and K. OGURO, A New Type of Capsule
Micropump Using ICPF Actuator, Proc.of 9th International Symposium on Micro Machine
and Human Science (MHS'98 ), Nagoya, 1998.
12.S. GUO, S. HATA, K. SUGIMOTO, T. FUKUDA and M. NEGORO, A New Type of Micro
Active Catheter System, Proc.of 1998 Symposium on ISSPR'98 on Image, Speech, Signal
Processing and Robotics, Vol.1, pp.335-340, Hong Kong, 1998.
13. S. GUO , S. HATA, K. SUGIMOTO, T. FUKUDA and K. OGURO, Development of A New Type
of Capsule Micropump, Proc. of 1999 IEEE International Conf. on Robotics and Automation,
pp.2171-2176, Detroit, USA (May, 1999).
14. S. GUO, N. KONDO and KATO, A Micro Intelligent Autonomous Moving Robot, Proc.of
1999 IEEE Hong Kong Symposium on Robotics and Control, Vol.1, pp.289-295, Hong Kong,
(July, 1999).
15. S. GUO, K. SUGIMOTO, T. FUKUDA and M. NEGORO, A New Type of Capsule Medical Micropump, Proc. of 1999 IEEE/ASME International Conf. on Advanced Intelligent Mechatronics, pp.55-60, Atlanta, GA, USA, (September,1999).
16. S. GUO, T. FUKUDA and K. OGURO, Development of an Artificial Fish Microrobot, Proc.of 10th International Symposium on Micro Machine and Human Science (MHS'99 ), pp.135-140, Nagoya (Vovember, 1999).
17. S. GUO, Micromechatronics for Medical Application (Development of Micro Active Catheter System and New Type of Micropumps), Proc.of China-Japan Workshop on Multidisciplinary Researches in Engineering, pp.30-34, Shanghai (Janu., 2000).
18. S. GUO, Micromechatronics for Medical Application (Development of Micro Active Catheter System and New Type of Micropumps), Proc.of China-Japan Workshop on Multidisciplinary Researches in Engineering, pp.30-34, Shanghai (Janu., 2000).
19. S. GUO, K.SUGIMOTO, S. HATA, K. OGURO, A Underwater Microrobot with Multi DOF, Proc. of International Symposium on Smart Structures and Microsystems (IS3M),pp.134-139,Hong Kong,(Oct., 2000).
20. S. GUO, K.Sugimoto, S. Hata, Development of a Macro/Micro Mechanism for Human Scale Teleoperating System, Proc.of 11th International Symposium on Micro Machine and Human Science (MHS'20 ),pp.163-168, Nagoya (Oct, 2000).
21. S. GUO, K.Sugimoto, S. Hata,J.Su, K.Oguro, A New Type of Underwater Fish-like Microrobot, IEEE Int. Conf. on Intelligent Robotics and Systems(IROS)'20, pp.867-862,Kagawa, Japan(Nov.,2000)
22. S. GUO, K.Oguro, Microsystems for Bio-medical Applications (Development of Micro Active Catheter System and New Type of Micropumps), Proc.of 2000 International Conf. On Information Society in the 21st Century, Emerging Technologies and new challenges (IS2000),pp.314-320, Aizu, Japan(Nov.,2000)
Return to home page(☆To Guo's Home Page)